期刊检索


检索
检索项:
检索词:
总目录
  • WCSB9︱2019(第九届)世界采样和混样大会 查看全文>>
  • 关于召开第十五届全国青年分析测试学术报告会的通知 查看全文>>
友情链接
不同类型探针对免疫层析方法的分析灵敏度影响研究
    点此下载全文
作者单位
马嘉琪,姚晓琳,刘思杰,殷雪驰,毕鹏飞,王建龙,张道宏 西北农林科技大学食品科学与工程学院陕西杨凌712100 
基金项目:陕西省重点研发计划项目(2019NY-109);大学生创新创业训练计划项目(X202010712305)
中文摘要:为研究不同类型探针对免疫层析方法的分析灵敏度影响,该研究以17β 雌二醇(17β E2)为检测对象,采用磁性纳米材料标记7 μg/mL的17β E2单克隆抗体(检测抗体)制备了传统探针,采用磁性纳米材料分别标记5 μg/mL的17β E2单克隆抗体和5 μg/mL的羊抗鼠IgG多克隆抗体(第二抗体)制备了配对探针,采用磁性纳米材料标记14 μg/mL的羊抗鼠IgG多克隆抗体制备了间接探针。然后,基于这3种不同类型的探针,分别建立了17β E2的免疫层析快速检测方法,并对3种17β E2免疫层析方法的检测灵敏度进行比较。结果显示,基于传统、配对和间接探针的免疫层析方法对17β E2的检出限分别为1、05、02 ng/mL,其中基于间接探针的免疫层析方法灵敏度最高,与基于传统探针和配对探针的免疫层析方法相比,检出限分别降低了5倍和25倍。该研究刷新了传统免疫层析方法中探针必须是信号材料标记检测抗体的认知,可为其他食品安全危害因子的免疫层析快速检测研究提供有价值的参考。
中文关键词:竞争免疫层析  探针  17β-雌二醇(17β E2)  食品安全
 
Study on Influences of Different Probes on Analytical Sensitivity of Immunochromatography Assay
Abstract:To study the influences of different probes on the analytical sensitivity of immunochromatography assay(ICA),a traditional probe was prepared for the detection of 17β estradiol(17β E2),with magnetic nanoparticles(MNPs) to label 7 μg/mL 17β E2 monoclonal antibody(mAb,detection Ab).Meanwhile,a paired probe was prepared by using MNPs to separately label 5 μg/mL 17β E2 mAb and 5 μg/mL goat anti-mouse polyclonal antibody(pAb,the second antibody),and an indirect probe was prepared by using MNPs to label 14 μg/mL pAb.Then,three immunochromatography assays were established based on the three probes for the rapid detection of estradiol.The analytical sensitivities of three ICAs were compared by the 17β E2 detection.Results showed that the analytical sensitivities of ICAs based on traditional,paired and indirect probes for 17β E2 are 1,05,02 ng/mL,respectively.Among these three ICAs,the analytical sensitivity of indirect probe based ICA is the highest.Compared with the traditional and paired probes based ICAs,the detection limit of the indirect probe based ICA is 5 fold and 25 fold reduced,respectively.This study refreshes the conventional cognition toward the signal probe which is considered can only be prepared by using signal materials to label the detection Ab in the traditional immunochromatography assay,and provides a valuable reference for the rapid detection of other food safety hazard factors by immunochromatography assays.
Key Words:competitive immunochromatography  probe  17β estradiol(17β E2)  food safety
引用本文:马嘉琪,姚晓琳,刘思杰,殷雪驰,毕鹏飞,王建龙,张道宏.不同类型探针对免疫层析方法的分析灵敏度影响研究[J].分析测试学报,2021,40(3):310-317.
摘要点击次数: 148
全文下载次数: 230
查看全文  下载PDF阅读器