高效液相色谱法测定食品接触材料及制品中9种酚类物质的迁移量
    点此下载全文
作者单位
刘桂华,苏凤,李威,寇海娟,眭洁,李晓曼,罗世鹏 1. 常州工业及消费品检验有限公司江苏 常州 213017 2. 南京海关危险货物与包装检测中心 江苏 常州 213022 3. 江苏理工学院 化学与环境工程学院江苏 常州 213001 
基金项目:江苏省自然科学基金青年项目(BK20201109);江苏理工学院产学研项目(KYH20072);南京海关科研计划项目(2020KJ26)
中文摘要:该文建立了苯酚、甲酚类、二甲酚类等9种酚类物质迁移量同时测定的高效液相色谱(HPLC)检测方法。采用Agilent ZORBAX SB-Aq色谱柱进行分离,以甲醇-水为流动相梯度洗脱,流速1.0 mL/min,荧光检测器测定,激发波长为214 nm,发射波长为315 nm。优化了含油脂食品模拟物中9种酚类物质的提取方式,并考察了线性范围、准确度及精密度等方法性能参数。研究结果表明,含油脂食品模拟物中9种酚类物质的最佳提取溶剂为67%甲醇溶液,9种酚类物质在水基及油脂类食品模拟物中的线性相关系数(r2)均高于0.999,回收率为90.7%~99.8%,相对标准偏差均低于6.0%。5种水基食品模拟物中9种酚类物质的定量下限为0.07~0.10 mg/L,橄榄油中9种酚类物质的定量下限为0.15~0.20 mg/kg。方法成功应用于11批食品接触用聚碳酸酯(PC)塑料制品、15批涂层制品中9种酚类物质迁移量的测定。该方法灵敏度高、精密度好,可为食品接触材料及制品中9种酚类物质迁移量的分析提供技术支持。
中文关键词:酚类物质  迁移  食品接触材料  高效液相色谱法(HPLC)  荧光检测器
 
Determination of Migration of 9 Phenols in Food Contact Materials by High Performance Liquid Chromatography
Abstract:A high performance liquid chromatographic(HPLC) method was established for the simultaneous determination of 9 phenols such as phenol,methyl-phenols and xylenols in food simulants. The sample was separated on an Agilent ZORBAX SB-Aq column by gradient elution,using methanol and water as mobile phase at a flow rate of 1.0 mL/min,and finally determined by fluorescence detection at an excitation wavelength of 214 nm and an emission wavelength of 315 nm.Meanwhile,the extraction method for 9 phenols in the fat-contained simulant was optimized,and the performances of the method including linearity,spiked recovery and precision were studied.Results demonstrated that 67% methanol aqueous solution was the best extraction solvent for the 9 phenols in fat simulants.The results also showed that there were good linear relationships for 9 phenols in all food simulants studied,with correlation coefficients(r2) higher than 0.999.The recoveries for 9 phenols at 3 spiked levels in all food simulants ranged from 90.7% to 99.8%,with relative standard deviations (RSD) all below 6.0%.The limits of quantitation(LOQs) were in the ranges of 0.07-0.10 mg/L for aqueous simulants,and 0.15-0.20 mg/kg for fat simulants. This method was successfully applied to the migration determination of 9 phenols released from 11 plastics articles(PC) and 15 coatings intended to contact with food.The method was sensitive and accurate,and was suitable for the determination of 9 phenols in food simulants.
Key Words:phenols  migration  food contact materials  high performance liquid chromatography (HPLC)  fluorescence detector
引用本文:刘桂华,苏凤,李威,寇海娟,眭洁,李晓曼,罗世鹏.高效液相色谱法测定食品接触材料及制品中9种酚类物质的迁移量[J].分析测试学报,2021,40(11):1619-1626.