Determination of 16 Phthalate Acid Esters in Water Samples by Magnetic Solid Phase Extraction/Gas Chromatography-Mass Spectrometry
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:magnetic multi-walled carbon nanotubes  magnetic solid phase extraction  phthalate acid esters(PAEs)  gas chromatography-mass spectrometry  water sample
  
AuthorInstitution
付善良,丁利,戴华,朱绍华,焦艳娜,龚强,陈继涛,吴新华,王利兵 1.湖南省检验检疫科学研究院湖南出入境检验检疫技术中心食品安全科学技术湖南省重点实验室.2.新疆出入境检验检疫技术中心
Hits: 2721
Download times: 1321
Abstract:
      A nanocomposite comprised of Fe3O4 magnetic nanoparticles(MNPs) and multi-walled carbon nanotubes(MWCNTs) was synthesized,and used as adsorbent in the determination of 16 PAEs in water samples by magnetic solid phase extraction(MSPE)and quantification by gas chromatography-mass spectrometry(GC-MS).The synthesis nano material was characterized by Fourier transform infrared spectroscopy.The factors affecting the extraction efficiency,such as type and amount of elution solvent,desorption time,adsorption time and pH value of water sample,were investigated.The optimized conditions were as follows:elution solvent:1 mL toluene-acetone(1∶4);desorption time:1 min;adsorption time:3 min;pH of water sample:5.0-7.0.The detection limits(S/N=3)for 16 PAEs were in the range of 0.035-0.255 μg/L and the quantitation limits(S/N=10) were 0.115-0.845 μg/L.The developed method was successfully applied in the analysis of 16 PAEs in tap water,lake water and river water.The recoveries at 3 spiked levels ranged from 87% to 112% with RSDs of 1.3%-11.9%.The results demonstrated that the MSPE method could be rapidly and effectively used in the monitoring of trace PAEs contaminants in water sample.