Determination of Free Hydroxyproline and Proline in Human Urine by Precolumn Derivation of MOBS-Cl
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:derivation  hydroxyproline  proline  4-methoxybenzenesulfonyl chlorine  high performance liquid chromatography  human urine
  
AuthorInstitution
周桂友,侯艳芳,董新吉,王赪胤 1.焦作出入境检验检疫局;2.焦作市中站区农林水利局;3.扬州大学化学化工学院
Hits: 3518
Download times: 1182
Abstract:
      A highly sensitive precolumn high performance liquid chromatographic(HPLC) method for the simultaneous determination of free hydroxyproline(Hyp) and proline(Pro) in human urine was developed.Effects of reaction temperature,pH value,time,concentration of labeling reagent,composition of moblie phase,concentration and pH value of buffer,and column temperature were investigated in detail.Under the optimal conditions,the calibration curves showed good linear relationship in the concentration ranges of 5-100 μmol/L for hydroxyproline and 5-250 μmol/L for proline.The correlation coefficients were 0.999 4 for hydroxyproline and 0.999 5 for proline.The detection limits(S/N=3) for hydroxyproline and proline were 0.50 nmol/L and 0.20 nmol/L,respectively.The recoveries(n=5) for hydroxyproline and proline were in the ranges of 95%-99% and 96%-102% with RSDs of 2.1%-4.3%and 2.0%-4.8%,respectively.This method can be used for the qualitative analysis of free hydroxyproline and proline in human urine sample.
Close