Determination of Pantothenic Acid in Human Urine by Liquid Chromatography- Tandem Mass Spectrometry
  
View Full Text    Download reader
DOI:
KeyWord:liquid chromatography tandem mass spectrometry  urine  pantothenic acid  biomonitoring
  
AuthorInstitution
ZHANG Xiao-tao,ZHANG Yun-fei,HOU Hong-wei,CHEN Huan,LIU Yong,WANG An,HU Qing-yuan 1.国家烟草质量监督检验中心;2.中国科学院合肥物质科学院应用技术所;3.河南省肿瘤医院
Hits: 1830
Download times: 881
Abstract:
      A liquid chromatography-tandem mass spectrometric(HPLC-MS/MS)method for the determination of pantothenic acid in urine was developed and validated.After centrifugation and dilution,the sample was separated on an ACPUITY UPLC HSS T3(2.1 mm×100 mm,1.8 μm) column produced by the Waters corporation,and ionized in electro spray positive ion mode,then detected using multi reaction monitoring mode.The calibration curve has a good linear range with a correlation coefficient(r) of 0.999 3.The limit of detection is 0.46 ng/mL,the recoveries are in the range of 87.9%-95.3%,and the RSDs are in the range of 2.5%-13.0%.The method has the advantages of high sensitivity and short analysis time,and could be used to analyze pantothenic acid in human urine.
Close