Determination on Content of Free Glycerol in Biodiesel by HPLC-ELSD
  
View Full Text    Download reader
DOI:10.3969/j.issn.1004-4957.年份.月份
KeyWord:high performance liquid chromatography(HPLC)  evaporative light-scattering detector(ELSD)  biodiesel  glycerol
  
AuthorInstitution
李蓉,王武生,马晓迅,陈斌 西北大学化工学院陕北能源先进化工利用技术教育部工程研究中心/陕西省洁净煤转化 工程技术研究中心
Hits: 2805
Download times: 1094
Abstract:
      An analytical method was established for the determination of free glycerol in biodiesel by using liquid-liquid extraction technique and high performance liquid chromatography(HPLC) with evaporative light-scattering detector(ELSD).The biodiesel sample was extracted with acetonitrile-water(75∶25),followed by centrifugation.The obtained aqueous layer was analyzed by HPLC-ELSD.The testing conditions of HPLC-ELSD were optimized and the optimal conditions were as follows:separation column:Inertsil NH2 column(250 mm×4.6 mm,5 μm),mobile phase:mixture of acetonitrile and water(75∶25),flow rate:1.0 mL/min,injection volume:30 μL,drift tube temperature:28 ℃,gas pressure of nebulizer:360 kPa.The result indicated that,under the optimal conditions,the calibration curve was linear over the content of free glycerol in biodiesel in the range of 3.73-302.0 mg/kg with a correlation coefficient of 0.999 8,and the limits of detection(S/N≥3)were 2.1 mg/kg.The spiked recoveries were in the range of 98%-101% with relative standard deviations(RSDs) of 0.59%-1.8%.The method was sensitive,accurate and reproducible,and could provide an efficient way for the determination of the content of free glycerol in biodiesel.